Connect the shielding to mass in the control
unit. This is the left contact on the
corresponding sensor connector terminals.
Please note that the following
measurements are based on values
provided by the unit quality assurance by the
European Standard EN 60335-2-53. In
principle, you must mount the oven sensor
where temperatures are expected to be the
highest. Illust. 6 gives you an overview of the
mounting point of the sensor.
Connecting the sauna lamp
The sauna lamp must be splashproof (by
Standard IPx4) and resistant to ambient
temperature. The sauna lamp can be
mounted anywhere except in the area of
the rising hot air above the oven.
Connecting the sensor lines
You should not install sensor and power
supply lines together, or lead them through
the same conduit. This can lead to
interferences in the electronics, such as
"fluttering" in the relays. If it is absolutely
necessary to install them together, or the
wire is longer than 3m, you should use a
shielded sensor line such as the LIYLY-O x
0.5 mm²).
Illust. 8Illust. 7
20 cm
Illust. 6
Mounting the oven sensor
1. Mount the oven sensor in cabins up to
2 x 2m according to Illust. 6 and 7, in larger
cabins according to Illust. 6 and 8.
19 cm
35 cm
Hole
Sensor housing
Sauna ceiling
Center sensor
housing on middle
section
Sensor line
Terminals in
the control unit
Illust. 9
2. Drill a hole to lead the cable through,
preferably through the middle of one of
the wooden boards.
3. Lead the sensor cable through the
drilled hole and attach it to the sensor
line according to Illust. 9.